Gate III · the planner
Zone and conduit planner
Write down your network the way a castle plan is drawn: zones (the baileys and the keep), the conduits that join them (the gates) and the flows you want to allow. The planner turns your list into a flow matrix and marks every flow between two zones that no conduit joins.
Nothing you type leaves this page and nothing is saved. Print the plan or copy it before you close the tab. The example below is for illustration only; clear it to start your own.
About the example plan: the zone names, devices and conduits are invented for illustration. Its ports are taken from the registry entries for Modbus TCP, 502 (mbap), OPC UA, 4840 (opcua), HTTPS, 443 and Remote Desktop, 3389 (ms-wbt-server) in the “Service Name and Transport Protocol Port Number Registry” published by the Internet Assigned Numbers Authority (IANA). The PROFINET flow is named “PROFINET RT” and has no port because PI (PROFIBUS and PROFINET International) describes PROFINET RT as running directly on Layer 2 Ethernet, separate from PROFINET traffic carried over TCP/IP or UDP/IP; see its “FAQ on PROFINET Basics” (PI North America).
Your plan
An estimate built only from your entries, not a security assessment.
Flow matrix
Rows are source zones, columns are destination zones.
Flow register
Zone register
How the planner works
In the zones and conduits model of the IEC 62443 series, a zone groups assets that share security requirements, and a conduit groups the communication channels between zones. The definitions are in IEC 62443-3-2:2020, “Security for industrial automation and control systems – Part 3-2: Security risk assessment for system design” (scope page, International Electrotechnical Commission). The International Society of Automation (ISA) publishes the series as “ISA/IEC 62443 Series of Standards” and explains the idea in “How to Define Zones and Conduits” (ISA, on automation.com). The planner applies a simplified version of that idea to your entries. Its matching rule is the planner’s own assumption, not wording from the standard: a conduit is treated as a two-way link between exactly two zones, and a flow counts as covered only when a conduit you entered joins its source zone and its destination zone directly (the zone pair is compared in either order).
- A flow whose source and destination are the same zone stays within the zone and crosses no conduit.
- A flow between two different zones is marked “conduit listed for this pair” when one of your conduits joins those two zones directly, in either direction. That is a match on the pair of zones only. The planner does not check what the conduit allows or whether it carries that protocol.
- Any other flow between two zones is marked “no conduit”: either add a conduit for it or remove the flow.
- Ports must be whole numbers from 1 to 65,535. TCP and UDP port numbers are 16-bit values (RFC 6335, section 6, IETF), and the IANA Service Name and Transport Protocol Port Number Registry reserves port 0, so this planner does not accept it. Type digits only, or thousands grouped with commas such as 65,535. An empty port is allowed for protocols that do not use one.
- A flow with a port that is not valid, or with no protocol, is listed in the flow register as “Needs correction” and is left out of the estimate until you fix it.
The planner is a planning sketch built only from what you type. It does not assess security levels, check firewall rules or measure compliance with the standard, and its limits (12 zones, 24 conduits, 60 flows) are its own. Check your design against the standard itself and your device documentation.